{"id":1169,"date":"2025-07-01T12:01:00","date_gmt":"2025-07-01T12:01:00","guid":{"rendered":"https:\/\/gwits.pl\/?p=1169"},"modified":"2026-02-25T23:10:41","modified_gmt":"2026-02-25T23:10:41","slug":"technologia-przeplywu-coriolisa-w-pomiarach-h2-i-co2-kluczowe-pytania-i-odpowiedzi-aby-umozliwic-niezawodny-pomiar-w-zastosowaniach-przemyslowych-coriolis-flow-technology-in-h2-and-co2-measurement","status":"publish","type":"post","link":"https:\/\/gwits.pl\/en\/technologia-przeplywu-coriolisa-w-pomiarach-h2-i-co2-kluczowe-pytania-i-odpowiedzi-aby-umozliwic-niezawodny-pomiar-w-zastosowaniach-przemyslowych-coriolis-flow-technology-in-h2-and-co2-measurement\/","title":{"rendered":"Technologia przep\u0142ywu Coriolisa w pomiarach H2 i CO2: kluczowe pytania i odpowiedzi, aby umo\u017cliwi\u0107 niezawodny pomiar w zastosowaniach przemys\u0142owych \/ Coriolis flow technology in H2 and CO2 measurement: key questions and answers to make reliable measurement happen in industrial applications"},"content":{"rendered":"\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Aleksandr Druzhkov, Yaser Alghanmi, Maarten Brugman, Salvatore Pitti, Raoul Blankestijn<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DOI:<strong> 10.15199\/17.2025.7-8.1<\/strong>,&nbsp;GWiTS 7-8\/2025, lipiec-sierpie\u0144&nbsp;2025<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/gazwoda.pl\/wp-content\/uploads\/Openaccess\/2025\/1015199172025781.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Pobierz PDF<\/a> (Open Access)<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Abstract:<br><\/strong>The need for reliable measurements of H<sub>2<\/sub> and CO<sub>2<\/sub> is no longer an industrial challenge connected only to process optimization goals. Accurate accountability of H<sub>2<\/sub> and CO<sub>2<\/sub> has become an essential requirement with wider social responsibility to mitigate the impact of global warming and achieve Net Zero Energy targets. As the industry advances projects to produce and transport H<sub>2<\/sub>, regulations and research projects attempt to develop the guidelines and legislations necessary to support accelerating readiness for the energy transition, while establishing a unified governance to the quality and measurement controls. Unlike H<sub>2<\/sub>, there are various forms of regulations, standards and legislations to govern CO<sub>2<\/sub> emissions. These can vary significantly as it relates to the control measures and methods. While the global economy reaches a uniform approach to define and govern the elements of H<sub>2<\/sub> and CO<sub>2<\/sub> for the purpose of the energy transition, the most urgent question is how to accurately account and report H<sub>2<\/sub> and CO<sub>2<\/sub>. The common consensus among industry leaders and technical researchers indicate that Coriolis Flow Metering is the most versatile and accurate technology to measure H<sub>2<\/sub> and CO<sub>2<\/sub> throughout the value chain in various phases.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em><strong>Keywords:<\/strong> carbon dioxide, Coriolis, measuring systems.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Streszczenie:<br><\/strong>Potrzeba wiarygodnych pomiar\u00f3w H<sub>2<\/sub> i CO<sub>2<\/sub> nie jest ju\u017c wyzwaniem przemys\u0142owym, zwi\u0105zanym wy\u0142\u0105cznie z celami optymalizacji proces\u00f3w. Dok\u0142adne rozliczanie H<sub>2<\/sub> i CO<sub>2<\/sub> sta\u0142o si\u0119 zasadniczym wymogiem, kt\u00f3ry wi\u0105\u017ce si\u0119 z szersz\u0105 odpowiedzialno\u015bci\u0105 spo\u0142eczn\u0105, w zakresie \u0142agodzenia skutk\u00f3w globalnego ocieplenia i osi\u0105gania cel\u00f3w zerowego zu\u017cycia energii netto.W miar\u0119 jak bran\u017ca rozwija projekty dotycz\u0105ce produkcji i transportu H<sub>2<\/sub>, przepisy i projekty badawcze d\u0105\u017c\u0105 do opracowania wytycznych i przepis\u00f3w, niezb\u0119dnych do przyspieszenia przygotowa\u0144 do transformacji energetycznej, przy jednoczesnym ustanowieniu jednolitego zarz\u0105dzania kontrol\u0105 jako\u015bci i pomiar\u00f3w. W przeciwie\u0144stwie do zagadnie\u0144 dotycz\u0105cych H<sub>2<\/sub>, istniej\u0105 r\u00f3\u017cne formy przepis\u00f3w, norm i ustawodawstwa reguluj\u0105cego emisj\u0119 CO<sub>2<\/sub>, kt\u00f3re mog\u0105 si\u0119 znacznie r\u00f3\u017cni\u0107 w odniesieniu do \u015brodk\u00f3w i metod kontroli. Chocia\u017c globalna gospodarka osi\u0105ga jednolite podej\u015bcie do definiowania i regulowania sk\u0142adnik\u00f3w H<sub>2<\/sub> i CO<sub>2<\/sub> na potrzeby transformacji energetycznej, to najpilniejszym pytaniem jest, jak dok\u0142adnie rozlicza\u0107 i raportowa\u0107 ilo\u015bci H<sub>2<\/sub> i CO<sub>2<\/sub>. Zgodnie ze wsp\u00f3ln\u0105 opini\u0105 lider\u00f3w bran\u017cy i badaczy technicznych, przep\u0142ywomierz Coriolisa jest najbardziej uniwersaln\u0105 i dok\u0142adn\u0105 technologi\u0105 pomiaru dla H<sub>2<\/sub> i CO<sub>2<\/sub> w ca\u0142ym \u0142a\u0144cuchu warto\u015bci na r\u00f3\u017cnych etapach.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em><strong>S\u0142owa kluczowe: <\/strong>dwutlenek w\u0119gla, Coriolis, systemy pomiarowe.<\/em><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Bibliografia<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[1] Alghanmi Y., Brugman M., Druzhkov A., Pitti S., Sautier S., Buttler M.2022. \u201cFlow Meter Performance for The New Hydrogen and Carbon Capture\u201d, Global Flow Measurement Workshop 25 \u2013 27 October 2022<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[2] Ammar A.A., Samah Z.N., Tye C.T.,Mohd R.O.,\u201d Evaluation of hydrogen concentration effect on the natural gas properties and flow performance\u201d, International Journal of Hydrogen Energy, 46 :974-983.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[3] Brown, R., Chinello, G., 2024. \u201cInvestigation of the transferability of calibration between alternative fluids for liquid and dense phase carbon dioxide flow measurement\u201d. Flow Measurement and Instrumentation, p.102644. <a href=\"https:\/\/doi.org\/10.1016\/j.flowmeasinst.2024.102644\">https:\/\/doi.org\/10.1016\/j.flowmeasinst.2024.102644<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[4] Collie G.J., Nazeri M., Jahanbakhsh A., Lin Ch-W., Maroto-Valer M.M.2017. \u201cReview of flowmeters for carbon dioxide transport in CCS applications\u201d, Greenhouse Gases: Science and Technology 7(1) :10-28.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[5] Costa F., Mills C., Garcia D., Gomez J., Pereira, L. O.,2023. \u201cOptimizing Coriolis Flowmeter Performance for the Brazilian O&amp;G Industry: Influence Factors and Calibration Strategies. Flow Measurement,\u201d 41st Global Flow Measurement Workshop, Norway, T\u00f8nsberg 24-26 October 2023.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[6] Gugole F., Schakel M. D., Druzhkov A., Brugman M.2024. \u201cAssessment of alternative fluid calibration to estimate traceable liquefied hydrogen flow measurement uncertainty\u201d. International Journal of Hydrogen Energy, 77, 2024, 1056-1065.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[7] Hemp J., Kutin J.,2006.\u201d Theory of errors in Coriolis flowmeter readings due to compressibility of the fluid being metered\u201d, Flow measurement and Instrumentation, vol. 17: 359-369.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[8] de Jonge T, Patten T, Rivetti A., Serio L.2002.\u201d Development of a mass flowmeter based on the Coriolis acceleration for liquid, supercritical and superfluid helium\u201d. 19th International Cryogenic Engineering Conference, Grenoble, France, 22 \u2013 26 Jul 2002, pp.647-650.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[9] Kocbach J.M., Holstad M.B., Sk\u00e5lvik A.M., Folger\u00f8 K., Ystad B., Lohne K.D., Soldal E.L., Losneg\u00e5rd S., Paulsen A., outon G., Teberikler L.2020.\u201d Where do we stand on flow metering for CO2 handling and storage?\u201d 38th International North Sea Flow Measurement Workshop, Aberdeen 26-29 October 2020.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[10] Liu R.P., Fuent M.J., Henry M.P., Duta M.D.2001.\u201d A neural network to correct mass flow errors caused by two-phase flow in a digital coriolis mass flowmeter\u201d. Flow Measurement and Instrumentation, 12(1): 53-63.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[11] Mills C., Chinello G.2022.\u201d Flow Measurement in support of Carbon Capture utilization and storage\u201d, FLOMEKO 2022, Chongqing, China. Online [accessed 22 April 2024].<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[12] Patten A.T., Garnett R.B. 2022.\u201d Method of compensating for mass flow using known density\u201d. US 11486752 B2.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[13] van Putten D., Kruithof R., Flow meter performance under CO2 gaseous conditions, North Sea Flow Measurement Workshop, Norway, T\u00f8nsberg 26-29 October 2021.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[14] Restelli F., Spatolisano E., Pellegrini L.A., Cattaneo S, de Angelis A.R., Lainati A., Roccaro E. 2024. \u201dLiquefied hydrogen value chain: A detailed techno-economic evaluation for its application in the industrial and mobility sectors\u201d, International Journal of Hydrogen Energy, 52: 454-466.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[15] Shuangjie Y., Guanwei J., Weiqing X., Rui L., Maolin C.2024.\u201d Numerical simulation of the transport and thermodynamic properties of imported natural gas injected with hydrogen in the manifold\u201d, International Journal of Hydrogen Energy, 55: 826-838.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[16] Spatolisano E., Restelli F., Pellegrini L.A., Cattaneo S., de Angelis A.R., Lainati A., Roccaro E. 2024. \u201dLiquefied hydrogen, ammonia and liquid organic hydrogen carriers for harbour-to-harbour hydrogen transport: A sensitivity study\u201d, International Journal of Hydrogen Energy, 80: 1424-1431.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[17] Tang P.W.2008.\u201d Measurement Uncertainty Analysis of a Close-loop High Pressure Turbine Meter Calibration Facility\u201d. Canadian Hydrocarbon Measurement School, Conference, Calgary. 2008, April.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[18] Valenta T., Literature Study: Use of Hydrogen in pipelines in Europe, MET4H2, 22 May 2024.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[19] Wetenhall B., Aghajani H., Chalmers H., Benson S.D., Ferrari M-C., Li J., Race J.M., Singh P., Davison J.2014.\u201d Impact of CO2 impurity on CO2 compression, liquefaction and transportation\u201d Energy Procedia (63): 2764 \u2013 2778.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[20] Wu T.Y., Kenbar A., Pruysen A.2021.\u201d LNG mass flowrate measurement using Coriolis flowmeters: Analysis of the measurement uncertainties\u201d, Measurement, Volume 177, 109258.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<div class=\"mh-excerpt\">Aleksandr Druzhkov, Yaser Alghanmi, Maarten Brugman, Salvatore Pitti, Raoul Blankestijn<\/div>\n<p> <a class=\"mh-excerpt-more\" href=\"https:\/\/gwits.pl\/en\/technologia-przeplywu-coriolisa-w-pomiarach-h2-i-co2-kluczowe-pytania-i-odpowiedzi-aby-umozliwic-niezawodny-pomiar-w-zastosowaniach-przemyslowych-coriolis-flow-technology-in-h2-and-co2-measurement\/\" title=\"Technologia przep\u0142ywu Coriolisa w pomiarach H2 i CO2: kluczowe pytania i odpowiedzi, aby umo\u017cliwi\u0107 niezawodny pomiar w zastosowaniach przemys\u0142owych \/ Coriolis flow technology in H2 and CO2 measurement: key questions and answers to make reliable measurement happen in industrial applications\"> &#8230;<\/a><\/p>","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[17],"tags":[37,38,39],"class_list":["post-1169","post","type-post","status-publish","format-standard","category-wszystkie_artykuly","tag-7-8-2025","tag-7-2025","tag-8-2025"],"_links":{"self":[{"href":"https:\/\/gwits.pl\/en\/wp-json\/wp\/v2\/posts\/1169","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gwits.pl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gwits.pl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gwits.pl\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/gwits.pl\/en\/wp-json\/wp\/v2\/comments?post=1169"}],"version-history":[{"count":5,"href":"https:\/\/gwits.pl\/en\/wp-json\/wp\/v2\/posts\/1169\/revisions"}],"predecessor-version":[{"id":2648,"href":"https:\/\/gwits.pl\/en\/wp-json\/wp\/v2\/posts\/1169\/revisions\/2648"}],"wp:attachment":[{"href":"https:\/\/gwits.pl\/en\/wp-json\/wp\/v2\/media?parent=1169"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gwits.pl\/en\/wp-json\/wp\/v2\/categories?post=1169"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gwits.pl\/en\/wp-json\/wp\/v2\/tags?post=1169"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}